류형록 | Engineering Portfolio · 전공 설계·실험

<aside> 📌

UI-100 / 900 W·300 Hz·220/110 V

계산 효율 96.360%·전압변동률 1.136%·Ku 0.312

회로·파형·계산

</aside>

2026-07-29 Source Case Reconciliation

Case η Regulation Ku 판단
DU-75 95.985% — — 96% 목표 미달
EI-112 initial 96.264% 2.018% 0.454 Ku 0.4 초과
EI-112 redesign 96.014% 2.289% 0.359 대안
UI-100 96.360% 1.136% 0.312 보고서 선택

UI-100 최종안: 220/110 V·900 W·300 Hz·180/93 turns·copper/core loss 10.2267/23.773 W. EI-190·UI-1.80MHW·TransformerCalc: 입력 정격별 별도 case. EI-190: #VALUE! 오류.

Calculation-Based Design · Source-Derived / Workbook Snapshot / Independent Recalculation

Transformer winding architecture

Transformer winding architecture

설계 조건

220/110 V, 900 W, 300 Hz 조건에서 DU·EI·UI 코어의 권선·손실·효율·전압변동률·창 이용률을 비교하고 UI-100 계산안을 선택했습니다.

Requirements

항목 값
--- ---:
Primary / Secondary 220 V / 110 V
Rated output 900 W
Frequency 300 Hz
Core material / Bmax Silicon steel / 1.5 T

Decision Flow

Core comparison flow

Core comparison flow

Case Efficiency Regulation Window use 판단
--- ---: ---: ---: ---
DU-75 95.985% — — Efficiency target not met
EI-112 first 96.264% 2.018% 0.454 Window use rejected
EI-112 redesign 96.014% 2.289% 0.359 Alternative
UI-100 final 96.360% 1.136% ≈0.312 Selected

Final Case